Triggers when: the ACC is in local mode.
The ACC can be put into local or remote mode by connecting to the remote
console.
9.2.7. MOPS Pol A counts out of bounds
Message ID: 38
Triggers when: Any of the Pol A GTP’s are below 0.1 or above 1.0
9.2.8. MOPS Pol B counts out of bounds
Message ID: 39
Triggers when: Any of the Pol B GTP’s are below 0.1 or above 1.0
9.3. Error Messages (Red)
These messages concern critical components of the telescope that have failed or
are about to fail. Your data taking abilities will be or already are impacted by
these messages.
9.3.1. Turret feed / translator disagree
Message ID: 5
Triggers when: 12mm feed is online and translator is not at 0.0mm
7mm feed is online and translator is not at 105.7 +/- 0.2mm
3mm feed is online and translator is not at 0.0mm
Alerts the observer to the feed not being on axis. Data taken while this error is
active will be unusable.
9.3.2. Turret translator control is not in remote
Message ID: 6
Triggers when: Turret translator remote control is set to Local
The receiver will not be able to be changed.
9.3.3. Severe lightning threat
Message ID: 9
Triggers when: The telescope is not stowed and the lightning threat level
equals 4.